C2412M (11/99)
BK700 Series Blower Kit
HK700 Series Heater Kit
®
IMPORTANT SAFEGUARDS AND WARNINGS
Prior to installation and use of this product, the following WARNINGS should be observed.
1. Installation and servicing should only be done by qualified service personnel and conform
to all local codes.
2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X ,6 or 6P
enclosure, it is designed for indoor use only and it must not be installed where exposed to
rain and moisture.
3. Only use replacement parts recommended by Pelco.
4. After replacement/repair of this unit’s electrical components, conduct a resistance
measurement between line and exposed parts to verify the exposed parts have not
been connected to line circuitry.
Please thoroughly familiarize yourself with the information in this manual prior to installation
and operation.
3500 Pelco Way
Clovis, CA 93612-5699
USA
In North America & Canada:
Tel (800) 289-9100
FAX (800) 289-9150
International Customers:
Tel +1 (559) 292-1981
FAX +1 (559) 348-1120
www.pelco.com
MODELS
Blower Kits
BK700 For use with E706 or E708 Series Enclosure, 120 VAC, 60 Hz, 4 watts,
10 cfm internal air circulation
BK700/220 Same as BK700 except 230 VAC, 50 Hz, 9 watts, 8 cfm internal air
circulation
BK700/24 Same as BK700 except 24 VAC, 3 watts, 19 cfm of internal air circulation
Heater Kits
HK706-1 Thermostatically controlled, 120 VAC, 80 watts, for E706 Series Enclosure
only. Activates ON at 40°F (4°C) and OFF at 60°F (16°C)
HK706-2 Same as HK706-1 except 24 VAC
HK706-3 Same as HK706-1 except 230 VAC
HK708/10-1 Thermostatically controlled, 120 VAC, 107 watts, for E708 Series
Enclosure only. Activates ON at 40°F (4°C) and OFF at 60°F (16°C)
HK708/10-2 Same as HK708/10-1 except 24 VAC, 66 watts
HK708/10-3 Same as HK708/10-1 except 230 VAC, 84 watts
INSTALLATION
CAUTION:
When a single power source is used for both the camera and
accessories, the camera power consumption must be taken into consideration
when determining the wire gauge. However, the following chart does not
include camera power because of the many variations.
Model Number Input Voltage Power Consumption Cable Size Cable Distance
BK700 120 VAC 4 watts 22 AWG 10,651 feet (3,246 m)
20 AWG 17,143 feet (5,225 m)
18 AWG 27,108 feet (8,262 m)
16 AWG 43,062 feet (13,125 m)
BK700/24 24 VAC 3 watts 20 AWG 914 feet (279 m)
18 AWG 1,446 feet (441 m)
16 AWG 2,297 feet (700 m)
14 AWG 3,650 feet (1,113 m)
Table A. Power Requirements and Recommended Cable Sizes
Continued on next page
Seitenansicht 0
1 2 3 4

Inhaltsverzeichnis

Seite 1 - HK700 Series Heater Kit

C2412M (11/99)BK700 Series Blower KitHK700 Series Heater Kit®IMPORTANT SAFEGUARDS AND WARNINGSPrior to installation and use of this product, the follo

Seite 2 - Blower Kit

Model Number Imput Voltage Power Consumption Cable Size Cable DistanceBK700/200 230 VAC 9 watts 20 AWG 25,609 feet (7,805 m)18 AWG 40,495 feet (12,342

Seite 3 - Heater Kit

Figure 1. Blower Kit InstallationHEATER BRACKET ASSEMBLYREAR PLATEPC BOARD ASSEMBLYCAMERA SLEDHeater KitIf you are installing the heater kit in conju