Pelco C3432M-F Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Sicherheitskameras Pelco C3432M-F herunter. Pelco C3432M-F User's Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - Camclosure

INSTALLATIONC3432M-F (6/08)Integrated Camera SystemIP110 Series Camclosure®

Seite 2 - Contents

10 C3432M-F (6/08)Cover and Back Box InstallationThe IP110 Series Camclosure integrated camera system mounts only to a surface. It can be wired throug

Seite 3 - List of Tables

C3432M-F (6/08) 114S ELECTRICAL BOX INSTALLATION1. Attach an ICS110-AP adapter plate (not supplied) to a 4S electrical box. Use two 8-32 x 0.75-inch P

Seite 4 - Important Safety Instructions

12 C3432M-F (6/08)404 PLASTER RING INSTALLATION1. Remove the two 8-32 x 0.375-inch Phillips pan head screws and washers to separate the cover from the

Seite 5 - Regulatory Notices

C3432M-F (6/08) 13SIDE CONDUIT INSTALLATION1. Remove the two 8-32 x 0.375-inch Phillips pan head screws and washers to separate the cover from the bac

Seite 6 - Open Source Software Notice

14 C3432M-F (6/08)Wiring TablesCAT5 CABLE Connect a Cat5 cable to the RJ-45 network connector. The 8-pin connector includes video and PoE for the came

Seite 7 - Description

C3432M-F (6/08) 15ALARM AND 24 VAC WIRESCONNECTING A RELAY DEVICEThe IP110 Camclosure has an output for triggering an external device. It supports bot

Seite 8 - Basic System Configurations

16 C3432M-F (6/08)CONNECTING ALARMSThe IP110 Camclosure provides an alarm input for external signaling devices, such as door contacts or motion detect

Seite 9 - NETMASK 255.255.0.0

C3432M-F (6/08) 17Unsupervised AlarmsWhen an alarm is configured as an unsupervised alarm, the Camclosure only triggers an alarm when the normal alarm

Seite 10 - BASIC SURFACE INSTALLATION

18 C3432M-F (6/08)Alarm ConnectionsFigure 14 shows how to wire the IP110 Camclosure to an alarm (refer to Wiring Tables on page 14).Figure 14. Unsuper

Seite 11 - C3432M-F (6/08) 11

C3432M-F (6/08) 19Camera ModuleThe IP110 Series Camclosure camera module includes the camera, camera bracket, and heater board. To perform most camera

Seite 12 - 404 PLASTER RING INSTALLATION

2 C3432M-F (6/08)ContentsImportant Safety Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 13 - SIDE CONDUIT INSTALLATION

20 C3432M-F (6/08)MODULE INSTALLATIONTo install the camera module into the back box:1. Plug the camera (10-pin), heater board (4-pin), and service (3-

Seite 14 - Wiring Tables

C3432M-F (6/08) 21Camera AdjustmentsTo perform camera adjustments, complete the following steps:1. Make sure the camera and service connectors are con

Seite 15 - ALARM AND 24 VAC WIRES

22 C3432M-F (6/08)VARIFOCAL LENS ZOOM AND FOCUS ADJUSTMENTSTo adjust the field of view and the focus:1. Select a field of view by turning the zoom adj

Seite 16 - CONNECTING ALARMS

C3432M-F (6/08) 23DN/CH SERIES ADJUSTMENTSRefer to Figure 19 to adjust the IP110-DN or IP110-CH model.Figure 19. Adjusting the IP110-DN/CH Series Camc

Seite 17 - Unsupervised Alarms

24 C3432M-F (6/08)SW4-4: FlickerlessIn certain lighting conditions, a flicker in the light source may affect camera operation. Flickering can be cause

Seite 18 - Alarm Connections

C3432M-F (6/08) 25DAY/NIGHT OPERATIONNOTE: This section only applies to DN model cameras.DN model cameras regularly check the brightness level of the

Seite 19 - Camera Module

26 C3432M-F (6/08)DW/CW SERIES (WIDE DYNAMIC RANGE) ADJUSTMENTSRefer to Figure 21 to adjust the IP110-DW or IP110-CW model.Figure 21. Adjusting the IP

Seite 20 - MODULE INSTALLATION

C3432M-F (6/08) 27SW1-4: Auto White Balance/Manual White BalanceAuto white balance (AWB) is enabled by default (ON).To manually set and lock the white

Seite 21 - Camera Adjustments

28 C3432M-F (6/08)Figure 20 and Table D show how the camera switches between color and black-white operation for each setting.Figure 22. DW Models Thr

Seite 22 - 22 C3432M-F (6/08)

C3432M-F (6/08) 29Camera PositioningManually rotate and tilt the camera module to position the camera. Then tighten the tilt screws (axis 1 in Figure

Seite 23 - DN/CH SERIES ADJUSTMENTS

C3432M-F (6/08) 3List of Illustrations1 DHCP Network Example. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 24 - BLEMISH DETECTION

30 C3432M-F (6/08)Install Dome and Trim Ring1. To adjust the dome liner refer to Figure 24 and complete the following steps:a. Align the screw holes i

Seite 25 - DAY/NIGHT OPERATION

C3432M-F (6/08) 31Service ConnectorThe IP110 Series Camclosure integrated camera system includes a service connector that outputs camera video. Use it

Seite 26 - DEFAULT SWITCH POSITION

32 C3432M-F (6/08)d. Solder the center connector of the cable to the center pin of the plug. e. Thread the braid of the cable through the hole in the

Seite 27 - SW1-7: Digital Slow Shutter

C3432M-F (6/08) 33Reset ButtonUse the reset button located on the board inside the back box to access the following modes:To access one of these modes

Seite 28 - AUTO IRIS LEVEL ADJUSTMENT

34 C3432M-F (6/08)TroubleshootingProblem Possible Cause Suggested RemedyNo video PoE power issue • Check Cat5 cable connection.• Verify PoE is enable

Seite 29 - Camera Positioning

C3432M-F (6/08) 35Image too light Installation error • Check DIP switch settings.• Use a service connector to check camera operation. Connect one end

Seite 30 - Install Dome and Trim Ring

36 C3432M-F (6/08)Network not working Faulty cable connection Check all cable connections and ensure all plugs are properly plugged in.Incorrect seria

Seite 31 - Service Connector

C3432M-F (6/08) 37SpecificationsGENERALPan/Tilt Adjustment ManualPan 360°Tilt 80° (20° to 100° range) Rotation 360°Construction Aluminum with steel ca

Seite 32 - 32 C3432M-F (6/08)

38 C3432M-F (6/08)ENVIRONMENTALEnvironment Low temperature, indoor/outdoorOperating Temperature -50° to 122°F (-46° to 50°C); de-ices to 25°F (-4°C)Th

Seite 33 - Reset Button

PRODUCT WARRANTY AND RETURN INFORMATIONWARRANTYPelco will repair or replace, without charge, any merchandise proved defective in material or workmansh

Seite 34 - Troubleshooting

4 C3432M-F (6/08)Important Safety Instructions1. Read these instructions.2. Keep these instructions.3. Heed all warnings.4. Follow all instructions.5.

Seite 35 - C3432M-F (6/08) 35

Worldwide Headquarters3500 Pelco WayClovis, California 93612 USAUSA & CanadaTel: (800) 289-9100Fax: (800) 289-9150InternationalTel: +1 (559) 292-1

Seite 36 - 36 C3432M-F (6/08)

C3432M-F (6/08) 5Regulatory NoticesThis device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this

Seite 37 - Specifications

6 C3432M-F (6/08)Open Source Software NoticeThis product includes certain open source or other software originated from third parties that is subject

Seite 38 - 38 C3432M-F (6/08)

C3432M-F (6/08) 7DescriptionThe IP110 Series Camclosure® is an indoor/outdoor, fixed mini dome system with a built-in 100Base-TX network interface for

Seite 39 - REVISION HISTORY

8 C3432M-F (6/08)Basic System ConfigurationsIMPORTANT NOTE. PLEASE READ. The network implementations in this document are shown as general representat

Seite 40

C3432M-F (6/08) 9Figure 3. Private Network ExampleFigure 4. Static Network ExampleIP110IP110WEB BROWSERNETWORK SWITCHIF NOT DHCP, CAMERA IS ASSIGNED

Kommentare zu diesen Handbüchern

Keine Kommentare